HPLC System with pump head 50ml
Description:
Advanced pump driver work a good performance, high precision, and better
stability; use high Electronic pulse suppression technology, pulsation reduce to min level; Substantially improve wavelength precision and stability of UV detector. Dual pump systems that can achieve gradient conditions can also perform operations such as degrees, which allow the operator to have more choices.
Ordering Details:
Item
|
PN
|
Product description
|
QTY
|
Unit
|
LC 3050 semi-prep Isocratic HPLC SYSTEM
|
1
|
set
|
1
|
L.F.P005
|
Semi-Preparative HPLC Pump ,with hump head 50ml
|
1
|
pcs
|
2
|
L.F.UV3023
|
UV 3000 UV Detector(Semi-Prep),with 50ml flow cell
|
1
|
pcs
|
3
|
I.K.A.A1359
|
A1359 Manual injection valve, 6-port/3-channel, stainless steel, 1/8", 300 bar, incl. accessories, Semi-Preparative
|
1
|
pcs
|
4
|
L.F.S.050
|
Start-up Kit for Isocratic Semi-Preparative
|
1
|
pcs
|
5
|
L.F.R3000
|
Solvent tray, analytical
|
1
|
pcs
|
6
|
A.G.103
|
CXTH 3000 Chromatography Workstation
|
1
|
pcs
|
Note:
* When the customers use the HPLC system for the first time, we suggest that solvent filter,
vacuum pump, ultrasonic cleaner, AC regulated power supply should be equipped.
Applications:
Purify products from micro gram level to gram level
1. High throughput screening active substance in drug development (phytomedicinem, microbial fermentation drug, synthetic drugs etc.)
2. Standard substance and reference substance preparation
3. Laboratory scale purification in research institute: from micro gram level to gram level
4. Purify impurities in drugs
5. Explore purification method for large scale purification
Technical parameter:
P3000 High-Pressure Infusion Pump
Technical Parameters
Flow Rate Range: ( 0 – 49.99 ) mL/min
Max Working Pressure: 25MPa
Flow Accuracy: ±2 % ( 5 mL/min)
Flow Repeatability: RSD ≤ 0.1 % ( 1 mL/min )
PSU: 220 V ± 22 V, 50 Hz, 120 W
Dimensions and Weights: 450 × 270 × 180 mm( L × W × H ) 12.8 kg
· UV3000 UV-VIS Detector
Wavelength Range: ( 190 - 700 ) nm
Light Source: D2 lamp (standard configuration), Tungsten lamp (optional available)
Band Width: 8 nm, Wavelength accuracy: ± 2nm, Wavelength repeatability:0.4nm
Baseline Noise: 1.5 × 10-5 AU/h
Baseline Drift: 4×10-4 AU/h
Dynamic: Velocity of flow 1mL/min; Methanol, wavelength 254 nm
Detection Cell Volume: 7uL
PSU: 220 V ± 22 V, 50 Hz, 150 W
Dimensions and Weights: 450 × 270 × 180 mm ( L × W × H ) 10.4 kg
Competitive Advantage:
1. Solvent transmission double plunger reciprocating pump, double plunger suction, small pulsation; Electronic compensation, velocity precision;
2. slow start, stop, max / min pressure adjustable, automatic storage of user data.
3. High voltage protection, more than the set pressure value automatically stops, 1/16’’pipeline connection, convenient and practical.
4. Signal detection 190-700nm detection wavelength range, more extensive scope of application.
5. GLP information function, convenient to check the total lighting time, lighting times, the replacement of equipment information and number of lamp product serial number.
6. Display 320×240 dot matrix LCD display, adjustable blue backlight, simple and generous.
7. Control Mode, Independent control mode: control by LCD panel buttons, set all parameters, makes the operation more flexible.
8. Computer control mode: connected through RS232 serial port, using CXTH workstation software control system.
9. The versatility. It can be used for positive and negative posture solvent system.
10. Be selective, common version and biological compatibility version independent choice.
11. Mainly used in the separated from the mixture of purified monomer
|